Slide Mask
Golden

Golden

Yerli Üretim
Advantages 
The inner surfaces of the boiler tanks are covered with a titanium-based enamel (Glassy Surface).By applying this process; the resistance against corrosion is increased in accordance with the usage purposes of boilers. As the surface roughness of the tank is reduced by this process, the accumulation of material and bacteria on the surface during its use is reduced to a large extent and system hygiene is ensured. Fast boilers prevent the formation of quenching zones thanks to their special serpentine designs. Titanium enamel coating prevents bacterial growth and corrosion. 

Working Principle 
They are pressure vessels that heat and store water in apartments and all kinds of facilities with a central hot water system thanks to the specially designed serpentine for the production and storage of clean hot water. A single serpentine boiler is a type of boiler which provides water heating and storage process with only one serpentine in it. There is an electronic controller in the forced circulation that controls the system. Thanks to this device, the temperatures of the collector and the boiler are measured and the necessary temperature is transferred to the boiler by means of the circulat on pump Such systems, like natural circulation  systems, do not necessarily have to lift the tank to a higher level than the collector
Icon
Icon
Icon
Icon
System Features
TypeOG-02-162OG-02-202OG-02-302OG-02-402OG-02-502OG-02-602OG-02-802OG-02-1002OG-02-1502OG-02-2002OG-02-2502OG-02-3002OG-02-4002OG-02-5000OG-02-6000
Capacity16020030040050060080010001500200025003000400050006000
Diameter (D)48058058075075075094010001200135014701470166016601760
Width (E)600700700870870870110011501350150016201620182018201920
Height (H)161014251900152518252025201020151988,5204021452660300035003750
Heating Area 1 (Serpentine-WAT1 bottom)0.82 m20.99 m21.60 m21.82 m22.28 m22.50 m23.26 m23.53 m23.97 m24.95 m25.92 m27.39 m28.5 m211.74 m212.66 m2
Heating Area 2 (Serpentine-WAT2 bottom)0.61 m20.80 m20.98 m21.15 m21.38 m21.60 m21.65 m21.80 m22.67 m22.73 m23 m23.46 m24.25 m26 m26.3 m2
Flange (ØT)DN 100DN 100DN 100DN 100DN 100DN 200DN 200DN 200DN 400DN 400DN 400DN 400DN 400DN 400DN 400
(M)320336336387387387477488717716755753120013801550
Max. Boiler Operation pressure10 bar10 bar10 bar10 bar10 bar10 bar10 bar10 bar10 bar10 bar10 bar10 bar10 bar10 bar10 bar
Max. Boiler Test pressure18 bar18 bar18 bar18 bar18 bar18 bar18 bar18 bar18 bar18 bar18 bar18 bar18 bar18 bar18 bar
Max. Boiler Working Temprature95 °C95 °C95 °C95 °C95 °C95 °C95 °C95 °C95 °C95 °C95 °C95 °C95 °C95 °C95 °C
Serpentine Operation pressure10 bar10 bar10 bar10 bar10 bar10 bar10 bar10 bar10 bar10 bar10 bar10 bar10 bar10 bar10 bar
Serpentine Test pressure18 bar18 bar18 bar18 bar18 bar18 bar18 bar18 bar18 bar18 bar18 bar18 bar18 bar18 bar18 bar
Max. Serpentine Working Temprature145 °C145 °C145 °C145 °C145 °C145 °C145 °C145 °C145 °C145 °C145 °C145 °C145 °C145 °C145 °C
Width107112140175195220295355540585630855180021502300